Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Background/Foreground Suppression
Housing Style
Rectangular w/M18 Mount
Primary Housing Material
Stainless Steel
Laser Classification
Class 1
Input/Output
Discrete
Indicator
Display; LED(s)
Analog Resolution/Discrete Repeatability
25 mm to 50 mm: +/-0.5; 50 mm to 300 mm: +/- 1% of range
Max Sensing Distance (mm)
300
Minimum Sensing Distance (mm)
25
Sensing Beam
Visible Red Laser
Power Supply
10-30 V dc
Delay at Power-up (ms)
750
Sensing Beam Wavelength (nm)
655
Adjustments
Push Button; Remote Teach
Temperature Effect (mm/°C)
+/- 0.05 mm/°C from 25 to 125 mm, +/- 0.35 mm/°C at 300 mm
Connection
Integral QD
QD Type/Cable Length
M12 (Euro) requires mating cordset
Number of Pins
5
Vibration
MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
MIL-STD-202G, Meth. 213B, Cond. I (100G 6x along X, Y & Z axes, 18 total shocks) w/ sensor operating
Output Saturation Voltage NPN Outputs
<1.0 V @ 100 mA
Output Saturation Voltage PNP Outputs
<1.5 V @ 100 mA
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
Bipolar (NPN & PNP)
Output Protection
Protected against continuous overload and short circuit
IP Rating
IP67; IP68; IP69K
Storage Temperature (°C)
-25 to 75
Max Operating Temperature (°C)
50
Min Operating Temperature (°C)
-10
Max Op. Relative Humidity Non-Condensing (%)
95 at 55°C
Window Material
Acrylic
Warm-up Time (minutes)
10
Minimum Response Time (ms)
1.5
Spot Size (@ Reference Distance)
2.0 mm x 0.8 mm @ 300 mm
Barrel Diameter (mm)
18
Minimum Window Size (mm)
0.4
Discrete Output Hysteresis (mm)
Automatically adjusted
Laser Control
Yes
Alarm Output (mA)
100
Max Ambient Light (Lux)
5000
Max Off-state Leakage Current (µA)
5 @ 30 V dc
Power/Current Consumption (exclusive of load)
< 675 mW
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Washdown Rated
Yes
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
Yes
Feature: Ecolab Certified
Yes
Feature: Chemical Resistant
Yes
IO link
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No
1-wire Serial Interface
No
Profibus
No